AC Current Measurement
① Rotate the switch to ACA 1000 A range.
② Keep the switch in its relaxed position (do not press).
③ Squeeze the trigger to open the jaw and clamp ONLY one conductor. Clamping two or more conductors will give invalid readings.
④ Read the display. If the value is below 200 A, switch to ACA 200 A for higher accuracy. If it is dark, press HOLD, move the meter to a brighter spot, then read the value.

 

latest company news about Clamp Meter – Quick Reference Guide  0

 

AC / DC Voltage Measurement
① For DC voltage, set the switch to ACA 200 A; for AC voltage, set it to ACV 750 V.
② Keep the switch relaxed.
③ Connect the red lead to V/Ω and the black lead to COM.
④ Place the probes in parallel across the circuit under test.

 

 

Resistance Measurement
① Select an appropriate resistance range.
② Keep the switch relaxed.
③ Red lead to V/Ω, black lead to COM.
④ Connect the probes across the resistor. For in-circuit measurements, power OFF the circuit and discharge any capacitors first.

 

 

Continuity Test
① Switch to 200 Ω range.
② Red lead to V/Ω, black lead to COM.
③ If the resistance between the probes is < (50 ± 25) Ω, the built-in buzzer will sound, indicating a closed circuit.

 

 

High Resistance (Insulation) Measurement
① Rotate the switch to “EXTERNAL UNIT” 20 MΩ or 2000 MΩ.
② Initial unstable readings are normal.
③ Insert the three accessory plugs into their respective jacks on the clamp meter.
④ Set both the clamp meter and accessory range to 2000 MΩ.
⑤ Connect the test leads to the accessory input terminals.
⑥ Turn on the accessory power, press PUSH; the indicator should light and the display will show the resistance. For values below 19 MΩ, use the 20 MΩ range for better accuracy.,

 

 

 

Company Information


Dongguan Habotest Instrument Technology Co.,Ltd is an innovation orientied technology enterprise with an over 20 years R&D team, injection molding, professional production line and assembly capabilities.
 
We offering professional and innovative measuring products as Digital Mltimeter, Digital Clamp Meter, Earth Resistane tester, Insulation Tester, Enviromental detector and other testing insturments for the worldwide customers to meet the global market demand, we also provide electronic test tools, measurement solutions and ODM and OEM services to specific customers.

 

 

banner
Blog Details
Created with Pixso. Home Created with Pixso. Blog Created with Pixso.

Clamp Meter – Quick Reference Guide

Clamp Meter – Quick Reference Guide

AC Current Measurement
① Rotate the switch to ACA 1000 A range.
② Keep the switch in its relaxed position (do not press).
③ Squeeze the trigger to open the jaw and clamp ONLY one conductor. Clamping two or more conductors will give invalid readings.
④ Read the display. If the value is below 200 A, switch to ACA 200 A for higher accuracy. If it is dark, press HOLD, move the meter to a brighter spot, then read the value.

 

latest company news about Clamp Meter – Quick Reference Guide  0

 

AC / DC Voltage Measurement
① For DC voltage, set the switch to ACA 200 A; for AC voltage, set it to ACV 750 V.
② Keep the switch relaxed.
③ Connect the red lead to V/Ω and the black lead to COM.
④ Place the probes in parallel across the circuit under test.

 

 

Resistance Measurement
① Select an appropriate resistance range.
② Keep the switch relaxed.
③ Red lead to V/Ω, black lead to COM.
④ Connect the probes across the resistor. For in-circuit measurements, power OFF the circuit and discharge any capacitors first.

 

 

Continuity Test
① Switch to 200 Ω range.
② Red lead to V/Ω, black lead to COM.
③ If the resistance between the probes is < (50 ± 25) Ω, the built-in buzzer will sound, indicating a closed circuit.

 

 

High Resistance (Insulation) Measurement
① Rotate the switch to “EXTERNAL UNIT” 20 MΩ or 2000 MΩ.
② Initial unstable readings are normal.
③ Insert the three accessory plugs into their respective jacks on the clamp meter.
④ Set both the clamp meter and accessory range to 2000 MΩ.
⑤ Connect the test leads to the accessory input terminals.
⑥ Turn on the accessory power, press PUSH; the indicator should light and the display will show the resistance. For values below 19 MΩ, use the 20 MΩ range for better accuracy.,

 

 

 

Company Information


Dongguan Habotest Instrument Technology Co.,Ltd is an innovation orientied technology enterprise with an over 20 years R&D team, injection molding, professional production line and assembly capabilities.
 
We offering professional and innovative measuring products as Digital Mltimeter, Digital Clamp Meter, Earth Resistane tester, Insulation Tester, Enviromental detector and other testing insturments for the worldwide customers to meet the global market demand, we also provide electronic test tools, measurement solutions and ODM and OEM services to specific customers.